Chapter 8 - Maintenance
Trouble shooting when display remains on intermediate error codes with 7-segment and point
alternatively flashing.
8.8.4.1. CASE 1
If it remains on this status:
Check STARC board (see chapter 8.9, page 232).
If STARC is OK:
Check wiring between STARC J302 and RSI J100.
Change the RSI.
8.8.4.2. CASE 2
If it remains on this status, the issue is related to STARC board (see chapter 8.9, page 232).
Problem:
- E flashing The RSI board is waiting to be synchronised with the STARC
board
Solution:
Problem:
- r flashing The STARC board is waiting to be synchronised with the
computer
Solution:
?
?