Robotics CS8C Bedienungsanleitung Seite 139

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 248
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 138
CS8C © Stäubli 2009 – D28070504A
139 / 248
Chapter 6 - Operation
6.8.2. STARTING UP IN MANUAL MODE
Once the application has been opened: (see paragraph 6.10.1)
Turn the 3-position keyswitch to the appropriate position. The selected mode is indicated both on WMS front
panel and on MCP (1).
Manual mode icon
Keep the validation button in its intermediate position or place the MCP on its holder (see paragraph 6.2.1).
Switch the arm power on by pressing the arm power button.
To start the application, press the Run key.
Run key
Command the movement by pressing the Move / Hold key
Move / Hold key
6.8.3. STARTING UP IN REMOTE MODE
In remote mode, the arm is powered up by an external system (external MCP, automatic controller) via a dedicated
digital input. The arm can also be powered up using the EnablePower instruction (see the Reference Manual for
the VAL3 language).
Once the application has been opened: (see paragraph 6.10.1)
Turn the 3-position keyswitch to the appropriate position. The selected mode is indicated both on WMS front
panel and on MCP (1).
Remote mode icon
To start the application, press the Run key.
Run key