7-4 Courier I-modem Getting Started Guide
2 Set the appropriate bus configuration.
To set Use this command
Point to point AT*M=0
Multipoint AT*M=1
3 Set up the ANALOG DEVICE B-channel.
a Set the Service Profile Identifier (SPID).
The command is AT*S1=n
Example: AT*S1=84755511110111 <Enter>
b Set the Directory Number (DN).
The command is AT*P1=n
Example: AT*P1=5551111
c Set the Terminal Endpoint Identifier (TEI), if you were
assigned one. If not, continue with step d.
The default setting is 0, or dynamic TEI assignment. The
TEI permanently identifies your link with the central office
switch.
The command is AT*T1=n
If your TEI Use this command
Is dynamic AT*T1=00
Is fixed AT*T1=n, where n is a number from 1 to 63.